26402-11 Health Care Facilities

1. Any facility that admits patients on electrical life support equipment must have a ________.

Question 1 of 25

2. Power to low-voltage equipment must be supplied from a(n) ________.

Question 2 of 25

3. Which part of an EES supplies power to major electrical equipment necessary for patient care and basic hospital operations?

Question 3 of 25

4. Line isolation monitors must have a green signal lamp that glows when the system is isolated from ground and located ________.

Question 4 of 25

5. In patient care areas, light fixtures are not required to be grounded using an insulated grounding conductor when they are more than how many feet above the floor?

Question 5 of 25

6. Installation of X-ray equipment is governed by ________.

Question 6 of 25

7. A room in which volatile flammable disinfecting agents are stored is considered a Class I, Division 1 location ________.

Question 7 of 25

8. A medication preparation area in a nursing home may have alternate power connected via a delayed automatic transfer device during a power failure in a ________.

Question 8 of 25

9. Individual branch circuits are not required for portable X-ray equipment requiring no more than ________.

Question 9 of 25

10. The life safety branch of an EES provides power to ________.

Question 10 of 25

11. Which of the following statements is true about Type MC cable in patient care areas?

Question 11 of 25

12. In addition to the NEC®, emergency electrical power for hospitals is governed by the ________.

Question 12 of 25

13. In a medical facility, receptacles should be mounted how many inches above the floor?

Question 13 of 25

14. Which of the following supplies power to the areas that are directly related to patient care, including emergency rooms and pharmacies?

Question 14 of 25

15. To limit impedance, which of the following should be sized at 10kVA or less?

Question 15 of 25

16. An equipotential ground plane ________.

Question 16 of 25

17. Health care facilities are often supplied by two or more distribution points; this is known as a(n) ________.

Question 17 of 25

18. Hospital-grade receptacles are ________.

Question 18 of 25

19. Patient bed locations in non-critical areas must have a minimum of ________.

Question 19 of 25

20. A No. 1 isolated conductor must be identified using which of the following colors?

Question 20 of 25

21. In a Type 3 EES, battery backup power must last for at least ________.

Question 21 of 25

22. Where receptacles will power digital electronic equipment, which of the following receptacles should be used?

Question 22 of 25

23. For X-ray equipment, the current rating of overcurrent protective devices must be the greater of at least 50% of the momentary rating or ________.

Question 23 of 25

24. Low-voltage equipment that is typically in contact with patients must be moisture-resistant and operate on ________.

Question 24 of 25

25. In a health care facility, a television is an example of a(n) ________.

Question 25 of 25