TAP Services(865) 919-6674

26403-11 Standby Emergency Systems

1. Which of the following commercial loads can be fed from a regular circuit rather than an emergency circuit?

Question 1 of 25

2. Optional standby systems are covered in ________.

Question 2 of 25

3. A storage battery must supply at least what percentage of the system voltage for the total load of circuits supplying legally required standby power?

Question 3 of 25

4. Battery capacity can be determined by ________.

Question 4 of 25

5. In lower-power UPS applications, the double-conversion UPS typically requires a DC power supply how many times larger than the full-load rating of the UPS?

Question 5 of 25

6. NEC Article 480 contains ________.

Question 6 of 25

7. Overcharging a lead-acid battery will ________.

Question 7 of 25

8. Which of the following is a requirement for generator sets used in legally required standby systems?

Question 8 of 25

9. Systems installed to protect loads such as communications, ventilation, or lighting systems that, when stopped, could create hazards or hamper rescue or fire-fighting operations are known as ________.

Question 9 of 25

10. In an AC generator, the field windings are energized by the ________.

Question 10 of 25

11. Transfer switches are sized based on ________.

Question 11 of 25

12. Which of the following are defined by the NEC® as those systems intended to protect public or private facilities or property where life safety does not depend on the performance of the system?

Question 12 of 25

13. Do not run an engine generator set without a load for more than ________.

Question 13 of 25

14. The most common method of cooling standby generator sets is ________.

Question 14 of 25

15. Battery starter systems used with generator sets are usually ________.

Question 15 of 25

16. Each patient bed location in a healthcare facility must be supplied by ________.

Question 16 of 25

17. A single-conversion UPS system ________.

Question 17 of 25

18. NEC Article 518 contains ________.

Question 18 of 25

19. When a lead-acid battery is being discharged ________.

Question 19 of 25

20. For every 15° above 77°, the life of a lead-acid battery is ________.

Question 20 of 25

21. An electronically controlled, solid-state power control system designed as an alternate source to provide regulated AC power to critical loads if the normal power system fails is commonly known as a(n) ________.

Question 21 of 25

22. The nominal open circuit voltage of a lead-acid cell is _____.

Question 22 of 25

23. The AC generator consists of a rotor and a(n) ________.

Question 23 of 25

24. Which type of engine-driven AC generator is commonly used as a standby system because they have a longer life and require less maintenance?

Question 24 of 25

25. Sizing of a generator set for a particular application is ________.

Question 25 of 25